85 lines
		
	
	
		
			2.7 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			85 lines
		
	
	
		
			2.7 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| Nuvoton NPCM7xx PWM and Fan Tacho controller device
 | |
| 
 | |
| The Nuvoton BMC NPCM7XX supports 8 Pulse-width modulation (PWM)
 | |
| controller outputs and 16 Fan tachometer controller inputs.
 | |
| 
 | |
| Required properties for pwm-fan node
 | |
| - #address-cells : should be 1.
 | |
| - #size-cells	: should be 0.
 | |
| - compatible	: "nuvoton,npcm750-pwm-fan" for Poleg NPCM7XX.
 | |
| - reg			: specifies physical base address and size of the registers.
 | |
| - reg-names	: must contain:
 | |
| 					* "pwm" for the PWM registers.
 | |
| 					* "fan" for the Fan registers.
 | |
| - clocks		: phandle of reference clocks.
 | |
| - clock-names	: must contain
 | |
| 					* "pwm" for PWM controller operating clock.
 | |
| 					* "fan" for Fan controller operating clock.
 | |
| - interrupts	: contain the Fan interrupts with flags for falling edge.
 | |
| - pinctrl-names	: a pinctrl state named "default" must be defined.
 | |
| - pinctrl-0	: phandle referencing pin configuration of the PWM and Fan
 | |
| 					controller ports.
 | |
| 
 | |
| fan subnode format:
 | |
| ===================
 | |
| Under fan subnode can be upto 8 child nodes, each child node representing a fan.
 | |
| Each fan subnode must have one PWM channel and atleast one Fan tach channel.
 | |
| 
 | |
| For PWM channel can be configured cooling-levels to create cooling device.
 | |
| Cooling device could be bound to a thermal zone for the thermal control.
 | |
| 
 | |
| Required properties for each child node:
 | |
| - reg : specify the PWM output channel.
 | |
| 	integer value in the range 0 through 7, that represent
 | |
| 	the PWM channel number that used.
 | |
| 
 | |
| - fan-tach-ch : specify the Fan tach input channel.
 | |
| 		integer value in the range 0 through 15, that represent
 | |
| 		the fan tach channel number that used.
 | |
| 
 | |
| 		At least one Fan tach input channel is required
 | |
| 
 | |
| Optional property for each child node:
 | |
| - cooling-levels: PWM duty cycle values in a range from 0 to 255
 | |
|                   which correspond to thermal cooling states.
 | |
| 
 | |
| Examples:
 | |
| 
 | |
| pwm_fan:pwm-fan-controller@103000 {
 | |
| 	#address-cells = <1>;
 | |
| 	#size-cells = <0>;
 | |
| 	compatible = "nuvoton,npcm750-pwm-fan";
 | |
| 	reg = <0x103000 0x2000>,
 | |
| 		<0x180000 0x8000>;
 | |
| 	reg-names = "pwm", "fan";
 | |
| 	clocks = <&clk NPCM7XX_CLK_APB3>,
 | |
| 		<&clk NPCM7XX_CLK_APB4>;
 | |
| 	clock-names = "pwm","fan";
 | |
| 	interrupts = <GIC_SPI 96 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 97 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 98 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 99 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 100 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 101 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 102 IRQ_TYPE_LEVEL_HIGH>,
 | |
| 			<GIC_SPI 103 IRQ_TYPE_LEVEL_HIGH>;
 | |
| 	pinctrl-names = "default";
 | |
| 	pinctrl-0 = <&pwm0_pins &pwm1_pins &pwm2_pins
 | |
| 			&fanin0_pins &fanin1_pins &fanin2_pins
 | |
| 			&fanin3_pins &fanin4_pins>;
 | |
| 	fan@0 {
 | |
| 		reg = <0x00>;
 | |
| 		fan-tach-ch = /bits/ 8 <0x00 0x01>;
 | |
| 		cooling-levels = <127 255>;
 | |
| 	};
 | |
| 	fan@1 {
 | |
| 		reg = <0x01>;
 | |
| 		fan-tach-ch = /bits/ 8 <0x02 0x03>;
 | |
| 	};
 | |
| 	fan@2 {
 | |
| 		reg = <0x02>;
 | |
| 		fan-tach-ch = /bits/ 8 <0x04>;
 | |
| 	};
 | |
| 
 | |
| };
 |