| What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory
 | |
| Date:		August 2021
 | |
| KernelVersion:	5.16
 | |
| Contact:	Jacopo Mondi <jacopo@jmondi.org>
 | |
| Description:
 | |
| 		Writing '1' triggers a 'Factory' calibration cycle.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background
 | |
| Date:		August 2021
 | |
| KernelVersion:	5.16
 | |
| Contact:	Jacopo Mondi <jacopo@jmondi.org>
 | |
| Description:
 | |
| 		Writing '1' triggers a 'Background' calibration cycle.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/error_status_available
 | |
| Date:		August 2021
 | |
| KernelVersion:	5.16
 | |
| Contact:	Jacopo Mondi <jacopo@jmondi.org>
 | |
| Description:
 | |
| 		Reading returns the list of possible chip error status.
 | |
| 		Available options are:
 | |
| 		- 'error_fatal': Analog front-end initialization error
 | |
| 		- 'error_i2c': Read/write to non-existing register
 | |
| 		- 'error_algorithm': Corrupted parameters
 | |
| 		- 'error_calibration': Calibration has failed
 | |
| 		- 'error_self_diagnostic': Internal interface failure
 | |
| 		- 'error_out_of_range': Measured concentration out of scale
 | |
| 		- 'error_memory': Error during memory operations
 | |
| 		- 'error_no_measurement': Cleared at first measurement
 | |
| 		- 'error_low_voltage': Sensor regulated voltage too low
 | |
| 		- 'error_measurement_timeout': Unable to complete measurement
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/error_status
 | |
| Date:		August 2021
 | |
| KernelVersion:	5.16
 | |
| Contact:	Jacopo Mondi <jacopo@jmondi.org>
 | |
| Description:
 | |
| 		Reading returns the current chip error status.
 |