| What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
 | |
| Date:		August 2015
 | |
| KernelVersion:	4.2.0
 | |
| Contact:	source@cogentembedded.com
 | |
| Description:
 | |
| 		Program sensor type for threshold detector inputs.
 | |
| 		Could be either "GND-Open" or "Supply-Open" mode. Y is a
 | |
| 		threshold detector input channel. Channels 0..7, 8..15, 16..23
 | |
| 		and 24..31 has common sensor types.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
 | |
| Date:		August 2015
 | |
| KernelVersion:	4.2.0
 | |
| Contact:	source@cogentembedded.com
 | |
| Description:
 | |
| 		Channel Y low voltage threshold. If sensor input voltage goes lower then
 | |
| 		this value then the threshold falling event is pushed.
 | |
| 		Depending on in_voltageY_sensing_mode the low voltage threshold
 | |
| 		is separately set for "GND-Open" and "Supply-Open" modes.
 | |
| 		Channels 0..31 have common low threshold values, but could have different
 | |
| 		sensing_modes.
 | |
| 
 | |
| 		The low voltage threshold range is between 2..21V.
 | |
| 		Hysteresis between low and high thresholds can not be lower then 2 and
 | |
| 		can not be odd.
 | |
| 
 | |
| 		If falling threshold results hysteresis to odd value then rising
 | |
| 		threshold is automatically subtracted by one.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
 | |
| Date:		August 2015
 | |
| KernelVersion:	4.2.0
 | |
| Contact:	source@cogentembedded.com
 | |
| Description:
 | |
| 		Channel Y high voltage threshold. If sensor input voltage goes higher then
 | |
| 		this value then the threshold rising event is pushed.
 | |
| 		Depending on in_voltageY_sensing_mode the high voltage threshold
 | |
| 		is separately set for "GND-Open" and "Supply-Open" modes.
 | |
| 
 | |
| 		Channels 0..31 have common high threshold values, but could have different
 | |
| 		sensing_modes.
 | |
| 
 | |
| 		The high voltage threshold range is between 3..22V.
 | |
| 		Hysteresis between low and high thresholds can not be lower then 2 and
 | |
| 		can not be odd.
 | |
| 
 | |
| 		If rising threshold results hysteresis to odd value then falling
 | |
| 		threshold is automatically appended by one.
 |