208 lines
		
	
	
		
			7.3 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			208 lines
		
	
	
		
			7.3 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| # SPDX-License-Identifier: GPL-2.0-only
 | |
| config MTD_AR7_PARTS
 | |
| 	tristate "TI AR7 partitioning parser"
 | |
| 	help
 | |
| 	  TI AR7 partitioning parser support
 | |
| 
 | |
| config MTD_BCM47XX_PARTS
 | |
| 	tristate "BCM47XX partitioning parser"
 | |
| 	depends on BCM47XX || ARCH_BCM_5301X
 | |
| 	help
 | |
| 	  This provides partitions parser for devices based on BCM47xx
 | |
| 	  boards.
 | |
| 
 | |
| config MTD_BCM63XX_PARTS
 | |
| 	bool "BCM63XX CFE partitioning parser"
 | |
| 	depends on BCM63XX || BMIPS_GENERIC || COMPILE_TEST
 | |
| 	select CRC32
 | |
| 	select MTD_PARSER_IMAGETAG
 | |
| 	help
 | |
| 	  This provides partition parsing for BCM63xx devices with CFE
 | |
| 	  bootloaders.
 | |
| 
 | |
| config MTD_BRCM_U_BOOT
 | |
| 	tristate "Broadcom's U-Boot partition parser"
 | |
| 	depends on ARCH_BCMBCA || COMPILE_TEST
 | |
| 	help
 | |
| 	  Broadcom uses a custom way of storing U-Boot environment variables.
 | |
| 	  They are placed inside U-Boot partition itself at unspecified offset.
 | |
| 	  It's possible to locate them by looking for a custom header with a
 | |
| 	  magic value. This driver does that and creates subpartitions for
 | |
| 	  each found environment variables block.
 | |
| 
 | |
| config MTD_CMDLINE_PARTS
 | |
| 	tristate "Command line partition table parsing"
 | |
| 	depends on MTD
 | |
| 	help
 | |
| 	  Allow generic configuration of the MTD partition tables via the kernel
 | |
| 	  command line. Multiple flash resources are supported for hardware where
 | |
| 	  different kinds of flash memory are available.
 | |
| 
 | |
| 	  You will still need the parsing functions to be called by the driver
 | |
| 	  for your particular device. It won't happen automatically. The
 | |
| 	  SA1100 map driver (CONFIG_MTD_SA1100) has an option for this, for
 | |
| 	  example.
 | |
| 
 | |
| 	  The format for the command line is as follows:
 | |
| 
 | |
| 	  mtdparts=<mtddef>[;<mtddef]
 | |
| 	  <mtddef>  := <mtd-id>:<partdef>[,<partdef>]
 | |
| 	  <partdef> := <size>[@offset][<name>][ro]
 | |
| 	  <mtd-id>  := unique id used in mapping driver/device
 | |
| 	  <size>    := standard linux memsize OR "-" to denote all
 | |
| 	  remaining space
 | |
| 	  <name>    := (NAME)
 | |
| 
 | |
| 	  Due to the way Linux handles the command line, no spaces are
 | |
| 	  allowed in the partition definition, including mtd id's and partition
 | |
| 	  names.
 | |
| 
 | |
| 	  Examples:
 | |
| 
 | |
| 	  1 flash resource (mtd-id "sa1100"), with 1 single writable partition:
 | |
| 	  mtdparts=sa1100:-
 | |
| 
 | |
| 	  Same flash, but 2 named partitions, the first one being read-only:
 | |
| 	  mtdparts=sa1100:256k(ARMboot)ro,-(root)
 | |
| 
 | |
| 	  If unsure, say 'N'.
 | |
| 
 | |
| config MTD_OF_PARTS
 | |
| 	tristate "OpenFirmware (device tree) partitioning parser"
 | |
| 	default y
 | |
| 	depends on OF
 | |
| 	help
 | |
| 	  This provides a open firmware device tree partition parser
 | |
| 	  which derives the partition map from the children of the
 | |
| 	  flash memory node, as described in
 | |
| 	  Documentation/devicetree/bindings/mtd/partition.txt.
 | |
| 
 | |
| config MTD_OF_PARTS_BCM4908
 | |
| 	bool "BCM4908 partitioning support"
 | |
| 	depends on MTD_OF_PARTS && (ARCH_BCMBCA || COMPILE_TEST)
 | |
| 	default ARCH_BCMBCA
 | |
| 	help
 | |
| 	  This provides partitions parser for BCM4908 family devices
 | |
| 	  that can have multiple "firmware" partitions. It takes care of
 | |
| 	  finding currently used one and backup ones.
 | |
| 
 | |
| config MTD_OF_PARTS_LINKSYS_NS
 | |
| 	bool "Linksys Northstar partitioning support"
 | |
| 	depends on MTD_OF_PARTS && (ARCH_BCM_5301X || ARCH_BCMBCA || COMPILE_TEST)
 | |
| 	default ARCH_BCM_5301X
 | |
| 	help
 | |
| 	  This provides partitions parser for Linksys devices based on Broadcom
 | |
| 	  Northstar architecture. Linksys commonly uses fixed flash layout with
 | |
| 	  two "firmware" partitions. Currently used firmware has to be detected
 | |
| 	  using CFE environment variable.
 | |
| 
 | |
| config MTD_PARSER_IMAGETAG
 | |
| 	tristate "Parser for BCM963XX Image Tag format partitions"
 | |
| 	depends on BCM63XX || BMIPS_GENERIC || COMPILE_TEST
 | |
| 	select CRC32
 | |
| 	help
 | |
| 	  Image Tag is the firmware header used by broadcom on their xDSL line
 | |
| 	  of devices. It is used to describe the offsets and lengths of kernel
 | |
| 	  and rootfs partitions.
 | |
| 	  This driver adds support for parsing a partition with an Image Tag
 | |
| 	  header and creates up to two partitions, kernel and rootfs.
 | |
| 
 | |
| config MTD_AFS_PARTS
 | |
| 	tristate "ARM Firmware Suite partition parsing"
 | |
| 	depends on (ARM || ARM64)
 | |
| 	help
 | |
| 	  The ARM Firmware Suite allows the user to divide flash devices into
 | |
| 	  multiple 'images'. Each such image has a header containing its name
 | |
| 	  and offset/size etc.
 | |
| 
 | |
| 	  If you need code which can detect and parse these tables, and
 | |
| 	  register MTD 'partitions' corresponding to each image detected,
 | |
| 	  enable this option.
 | |
| 
 | |
| 	  You will still need the parsing functions to be called by the driver
 | |
| 	  for your particular device. It won't happen automatically. The
 | |
| 	  'physmap' map driver (CONFIG_MTD_PHYSMAP) does this, for example.
 | |
| 
 | |
| config MTD_PARSER_TRX
 | |
| 	tristate "Parser for TRX format partitions"
 | |
| 	depends on MTD && (BCM47XX || ARCH_BCM_5301X || ARCH_MEDIATEK || RALINK || COMPILE_TEST)
 | |
| 	help
 | |
| 	  TRX is a firmware format used by Broadcom on their devices. It
 | |
| 	  may contain up to 3/4 partitions (depending on the version).
 | |
| 	  This driver will parse TRX header and report at least two partitions:
 | |
| 	  kernel and rootfs.
 | |
| 
 | |
| config MTD_SHARPSL_PARTS
 | |
| 	tristate "Sharp SL Series NAND flash partition parser"
 | |
| 	depends on MTD_NAND_SHARPSL || MTD_NAND_TMIO || COMPILE_TEST
 | |
| 	help
 | |
| 	  This provides the read-only FTL logic necessary to read the partition
 | |
| 	  table from the NAND flash of Sharp SL Series (Zaurus) and the MTD
 | |
| 	  partition parser using this code.
 | |
| 
 | |
| config MTD_REDBOOT_PARTS
 | |
| 	tristate "RedBoot partition table parsing"
 | |
| 	help
 | |
| 	  RedBoot is a ROM monitor and bootloader which deals with multiple
 | |
| 	  'images' in flash devices by putting a table one of the erase
 | |
| 	  blocks on the device, similar to a partition table, which gives
 | |
| 	  the offsets, lengths and names of all the images stored in the
 | |
| 	  flash.
 | |
| 
 | |
| 	  If you need code which can detect and parse this table, and register
 | |
| 	  MTD 'partitions' corresponding to each image in the table, enable
 | |
| 	  this option.
 | |
| 
 | |
| 	  You will still need the parsing functions to be called by the driver
 | |
| 	  for your particular device. It won't happen automatically. The
 | |
| 	  SA1100 map driver (CONFIG_MTD_SA1100) has an option for this, for
 | |
| 	  example.
 | |
| 
 | |
| if MTD_REDBOOT_PARTS
 | |
| 
 | |
| config MTD_REDBOOT_DIRECTORY_BLOCK
 | |
| 	int "Location of RedBoot partition table"
 | |
| 	default "-1"
 | |
| 	help
 | |
| 	  This option is the Linux counterpart to the
 | |
| 	  CYGNUM_REDBOOT_FIS_DIRECTORY_BLOCK RedBoot compile time
 | |
| 	  option.
 | |
| 
 | |
| 	  The option specifies which Flash sectors holds the RedBoot
 | |
| 	  partition table.  A zero or positive value gives an absolute
 | |
| 	  erase block number. A negative value specifies a number of
 | |
| 	  sectors before the end of the device.
 | |
| 
 | |
| 	  For example "2" means block number 2, "-1" means the last
 | |
| 	  block and "-2" means the penultimate block.
 | |
| 
 | |
| config MTD_REDBOOT_PARTS_UNALLOCATED
 | |
| 	bool "Include unallocated flash regions"
 | |
| 	help
 | |
| 	  If you need to register each unallocated flash region as a MTD
 | |
| 	  'partition', enable this option.
 | |
| 
 | |
| config MTD_REDBOOT_PARTS_READONLY
 | |
| 	bool "Force read-only for RedBoot system images"
 | |
| 	help
 | |
| 	  If you need to force read-only for 'RedBoot', 'RedBoot Config' and
 | |
| 	  'FIS directory' images, enable this option.
 | |
| 
 | |
| endif # MTD_REDBOOT_PARTS
 | |
| 
 | |
| config MTD_QCOMSMEM_PARTS
 | |
| 	tristate "Qualcomm SMEM flash partition parser"
 | |
| 	depends on QCOM_SMEM
 | |
| 	help
 | |
| 	  This provides support for parsing partitions from Shared Memory (SMEM)
 | |
| 	  for NAND and SPI flash on Qualcomm platforms.
 | |
| 
 | |
| config MTD_SERCOMM_PARTS
 | |
| 	tristate "Sercomm partition table parser"
 | |
| 	depends on MTD && RALINK
 | |
| 	help
 | |
| 	  This provides partitions table parser for devices with Sercomm
 | |
| 	  partition map. This partition table contains real partition
 | |
| 	  offsets, which may differ from device to device depending on the
 | |
| 	  number and location of bad blocks on NAND.
 |