| // SPDX-License-Identifier: GPL-2.0
 | |
| /*
 | |
|  * Fuel gauge driver for CellWise 2017
 | |
|  *
 | |
|  * Copyright (C) 2012, Rockchip Electronics Co., Ltd.
 | |
|  *
 | |
|  * Authors: Shunqing Chen <csq@rock-chips.com>
 | |
|  */
 | |
| 
 | |
| #include <linux/bits.h>
 | |
| #include <linux/delay.h>
 | |
| #include <linux/i2c.h>
 | |
| #include <linux/gfp.h>
 | |
| #include <linux/gpio/consumer.h>
 | |
| #include <linux/kernel.h>
 | |
| #include <linux/module.h>
 | |
| #include <linux/power_supply.h>
 | |
| #include <linux/property.h>
 | |
| #include <linux/regmap.h>
 | |
| #include <linux/time.h>
 | |
| #include <linux/workqueue.h>
 | |
| #include <linux/devm-helpers.h>
 | |
| 
 | |
| #define CW2017_SIZE_BATINFO		80
 | |
| 
 | |
| #define CW2017_REG_VERSION		0x00
 | |
| #define CW2017_REG_VCELL_H		0x02
 | |
| #define CW2017_REG_VCELL_L		0x03
 | |
| #define CW2017_REG_SOC_INT		0x04
 | |
| #define CW2017_REG_SOC_DECIMAL		0x05
 | |
| #define CW2017_REG_TEMP			0x06
 | |
| #define CW2017_REG_MODE_CONFIG		0x08
 | |
| #define CW2017_REG_INT_CONFIG		0x0A
 | |
| #define CW2017_REG_SOC_ALERT		0x0B
 | |
| #define CW2017_REG_TEMP_MAX		0x0C
 | |
| #define CW2017_REG_TEMP_MIN		0x0D
 | |
| #define CW2017_REG_VOLT_ID_H		0x0E
 | |
| #define CW2017_REG_VOLT_ID_L		0x0F
 | |
| #define CW2017_REG_BATINFO		0x10
 | |
| 
 | |
| #define CW2017_MODE_SLEEP		0x30
 | |
| #define CW2017_MODE_NORMAL		0x00
 | |
| #define CW2017_MODE_DEFAULT		0xF0
 | |
| 
 | |
| #define CW2017_CONFIG_UPDATE_FLG	0x80
 | |
| #define NO_START_VERSION		160
 | |
| 
 | |
| #define	TEMP_MAX_ALERT			0xFFFF
 | |
| #define	TEMP_MIN_ALERT			0xFFFF
 | |
| #define TEMP_ALERT_DISABLE		0xFFFF
 | |
| 
 | |
| #define INT_CONFIG_MIN_TEMP_MARK        BIT(4)
 | |
| #define INT_CONFIG_MAX_TEMP_MARK        BIT(5)
 | |
| #define INT_CONFIG_SOC_CHANGE_MARK      BIT(6)
 | |
| 
 | |
| #define DEF_DESIGN_CAPACITY		4000
 | |
| 
 | |
| #define CW2017_MASK_ATHD		GENMASK(7, 0)
 | |
| 
 | |
| /* reset gauge of no valid state of charge could be polled for 40s */
 | |
| #define CW2017_BAT_SOC_ERROR_MS		(40 * MSEC_PER_SEC)
 | |
| /* reset gauge if state of charge stuck for half an hour during charging */
 | |
| #define CW2017_BAT_CHARGING_STUCK_MS	(1800 * MSEC_PER_SEC)
 | |
| 
 | |
| /* poll interval from CellWise GPL Android driver example */
 | |
| #define CW2017_DEFAULT_POLL_INTERVAL_MS	8000
 | |
| 
 | |
| struct cw_battery {
 | |
| 	struct device *dev;
 | |
| 	struct workqueue_struct *battery_workqueue;
 | |
| 	struct delayed_work battery_delay_work;
 | |
| 	struct regmap *regmap;
 | |
| 	struct power_supply *rk_bat;
 | |
| 	struct power_supply_battery_info *battery;
 | |
| 	u8 *bat_profile;
 | |
| 
 | |
| 	bool charger_attached;
 | |
| 	bool battery_changed;
 | |
| 
 | |
| 	int soc;
 | |
| 	int voltage_mv;
 | |
| 	int status;
 | |
| 	int charge_count;
 | |
| 	int design_capacity;
 | |
| 
 | |
| 	u32 poll_interval_ms;
 | |
| 	u32 alert_level;
 | |
| 	int temp_max;
 | |
| 	int temp_min;
 | |
| 	int temp;
 | |
| 
 | |
| 	bool dual_cell;
 | |
| 
 | |
| 	unsigned int read_errors;
 | |
| 	unsigned int charge_stuck_cnt;
 | |
| };
 | |
| 
 | |
| static int cw_read_word(struct cw_battery *cw_bat, u8 reg, u16 *val)
 | |
| {
 | |
| 	__be16 value;
 | |
| 	int ret;
 | |
| 
 | |
| 	ret = regmap_bulk_read(cw_bat->regmap, reg, &value, sizeof(value));
 | |
| 	if (ret)
 | |
| 		return ret;
 | |
| 
 | |
| 	*val = be16_to_cpu(value);
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static void cw2017_enable(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	unsigned char reg_val = CW2017_MODE_DEFAULT;
 | |
| 
 | |
| 	regmap_write(cw_bat->regmap, CW2017_REG_MODE_CONFIG, reg_val);
 | |
| 	msleep(20);
 | |
| 	reg_val = CW2017_MODE_SLEEP;
 | |
| 	regmap_write(cw_bat->regmap, CW2017_REG_MODE_CONFIG, reg_val);
 | |
| 	msleep(20);
 | |
| 	reg_val = CW2017_MODE_NORMAL;
 | |
| 	regmap_write(cw_bat->regmap, CW2017_REG_MODE_CONFIG, reg_val);
 | |
| 	msleep(20);
 | |
| }
 | |
| 
 | |
| static int cw_update_profile(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int ret;
 | |
| 	unsigned int reg_val = 0;
 | |
| 	unsigned char int_mask = 0;
 | |
| 
 | |
| 	/* write new battery info */
 | |
| 	ret = regmap_raw_write(cw_bat->regmap, CW2017_REG_BATINFO,
 | |
| 			       cw_bat->bat_profile,
 | |
| 			       CW2017_SIZE_BATINFO);
 | |
| 	if (ret)
 | |
| 		return ret;
 | |
| 
 | |
| 	/* set config update flag  */
 | |
| 	reg_val |= CW2017_CONFIG_UPDATE_FLG;
 | |
| 	reg_val &= ~CW2017_MASK_ATHD;
 | |
| 	reg_val |= cw_bat->alert_level;
 | |
| 	regmap_write(cw_bat->regmap, CW2017_REG_SOC_ALERT, reg_val);
 | |
| 
 | |
| 	if (cw_bat->alert_level)
 | |
| 		int_mask |= INT_CONFIG_SOC_CHANGE_MARK;
 | |
| 
 | |
| 	cw_bat->temp_max = TEMP_MAX_ALERT;
 | |
| 	cw_bat->temp_min = TEMP_MIN_ALERT;
 | |
| 	if (cw_bat->temp_max != TEMP_ALERT_DISABLE) {
 | |
| 		int_mask |= INT_CONFIG_MAX_TEMP_MARK;
 | |
| 		reg_val = (cw_bat->temp_max + 40) * 2;
 | |
| 		regmap_write(cw_bat->regmap, CW2017_REG_TEMP_MAX, reg_val);
 | |
| 	}
 | |
| 	if (cw_bat->temp_min != TEMP_ALERT_DISABLE) {
 | |
| 		int_mask |= INT_CONFIG_MIN_TEMP_MARK;
 | |
| 		reg_val = (cw_bat->temp_min + 40) * 2;
 | |
| 		regmap_write(cw_bat->regmap, CW2017_REG_TEMP_MIN, reg_val);
 | |
| 	}
 | |
| 	regmap_write(cw_bat->regmap, CW2017_REG_INT_CONFIG, int_mask);
 | |
| 
 | |
| 	/* wait for gauge to reset */
 | |
| 	msleep(20);
 | |
| 
 | |
| 	/* wait for gauge to become ready */
 | |
| 	ret = regmap_read_poll_timeout(cw_bat->regmap, CW2017_REG_SOC_INT,
 | |
| 				       reg_val, reg_val <= 100,
 | |
| 				       10 * USEC_PER_MSEC, 10 * USEC_PER_SEC);
 | |
| 	if (ret)
 | |
| 		dev_err(cw_bat->dev,
 | |
| 			"Gauge did not become ready after profile upload\n");
 | |
| 	else
 | |
| 		dev_dbg(cw_bat->dev, "Battery profile updated\n");
 | |
| 
 | |
| 	cw2017_enable(cw_bat);
 | |
| 	dev_dbg(cw_bat->dev, "Battery profile configured\n");
 | |
| 
 | |
| 	return ret;
 | |
| }
 | |
| 
 | |
| static int cw_init(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int ret;
 | |
| 	unsigned int reg_val;
 | |
| 	unsigned int config_flg;
 | |
| 
 | |
| 	regmap_read(cw_bat->regmap, CW2017_REG_MODE_CONFIG, ®_val);
 | |
| 	regmap_read(cw_bat->regmap, CW2017_REG_SOC_ALERT, &config_flg);
 | |
| 
 | |
| 	if (reg_val != CW2017_MODE_NORMAL || !(config_flg & CW2017_CONFIG_UPDATE_FLG)) {
 | |
| 		dev_dbg(cw_bat->dev,
 | |
| 			"Battery profile not present, uploading battery profile\n");
 | |
| 		if (cw_bat->bat_profile) {
 | |
| 			ret = cw_update_profile(cw_bat);
 | |
| 			if (ret) {
 | |
| 				dev_err(cw_bat->dev,
 | |
| 					"Failed to upload battery profile\n");
 | |
| 				return ret;
 | |
| 			}
 | |
| 		} else {
 | |
| 			dev_warn(cw_bat->dev,
 | |
| 				 "No profile specified, continuing without profile\n");
 | |
| 		}
 | |
| 	} else if (cw_bat->bat_profile) {
 | |
| 		u8 bat_info[CW2017_SIZE_BATINFO];
 | |
| 
 | |
| 		ret = regmap_raw_read(cw_bat->regmap, CW2017_REG_BATINFO,
 | |
| 				      bat_info, CW2017_SIZE_BATINFO);
 | |
| 		if (ret) {
 | |
| 			dev_err(cw_bat->dev,
 | |
| 				"Failed to read stored battery profile\n");
 | |
| 			return ret;
 | |
| 		}
 | |
| 
 | |
| 		if (memcmp(bat_info, cw_bat->bat_profile, CW2017_SIZE_BATINFO)) {
 | |
| 			dev_warn(cw_bat->dev, "Replacing stored battery profile\n");
 | |
| 			ret = cw_update_profile(cw_bat);
 | |
| 			if (ret)
 | |
| 				return ret;
 | |
| 		}
 | |
| 	} else {
 | |
| 		dev_warn(cw_bat->dev,
 | |
| 			 "Can't check current battery profile, no profile provided\n");
 | |
| 	}
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| #define HYSTERESIS(current, previous, up, down) \
 | |
| 	(((current) < (previous) + (up)) && ((current) > (previous) - (down)))
 | |
| 
 | |
| static int cw_get_soc(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	unsigned int soc;
 | |
| 
 | |
| 	regmap_read(cw_bat->regmap, CW2017_REG_SOC_INT, &soc);
 | |
| 	if (soc > 100) {
 | |
| 		int max_error_cycles =
 | |
| 			CW2017_BAT_SOC_ERROR_MS / cw_bat->poll_interval_ms;
 | |
| 
 | |
| 		dev_err(cw_bat->dev, "Invalid SoC %d%%\n", soc);
 | |
| 		cw_bat->read_errors++;
 | |
| 		if (cw_bat->read_errors > max_error_cycles) {
 | |
| 			dev_warn(cw_bat->dev,
 | |
| 				 "Too many invalid SoC reports, resetting gauge\n");
 | |
| 			cw_bat->read_errors = 0;
 | |
| 		}
 | |
| 		return cw_bat->soc;
 | |
| 	}
 | |
| 	cw_bat->read_errors = 0;
 | |
| 
 | |
| 	/* Reset gauge if stuck while charging */
 | |
| 	if (cw_bat->status == POWER_SUPPLY_STATUS_CHARGING && soc == cw_bat->soc) {
 | |
| 		int max_stuck_cycles =
 | |
| 			CW2017_BAT_CHARGING_STUCK_MS / cw_bat->poll_interval_ms;
 | |
| 
 | |
| 		cw_bat->charge_stuck_cnt++;
 | |
| 		if (cw_bat->charge_stuck_cnt > max_stuck_cycles) {
 | |
| 			dev_warn(cw_bat->dev,
 | |
| 				 "SoC stuck @%u%%, resetting gauge\n", soc);
 | |
| 			cw_bat->charge_stuck_cnt = 0;
 | |
| 		}
 | |
| 	} else {
 | |
| 		cw_bat->charge_stuck_cnt = 0;
 | |
| 	}
 | |
| 
 | |
| 	/* Ignore voltage dips during charge */
 | |
| 	if (cw_bat->charger_attached && HYSTERESIS(soc, cw_bat->soc, 0, 3))
 | |
| 		soc = cw_bat->soc;
 | |
| 
 | |
| 	/* Ignore voltage spikes during discharge */
 | |
| 	if (!cw_bat->charger_attached && HYSTERESIS(soc, cw_bat->soc, 3, 0))
 | |
| 		soc = cw_bat->soc;
 | |
| 
 | |
| 	return soc;
 | |
| }
 | |
| 
 | |
| static int cw_get_voltage(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int voltage_mv;
 | |
| 	u16 reg_val = 0;
 | |
| 
 | |
| 	cw_read_word(cw_bat, CW2017_REG_VCELL_H, ®_val);
 | |
| 	reg_val &= 0x3fff;
 | |
| 	voltage_mv = reg_val * 5 / 16;
 | |
| 	if (cw_bat->dual_cell)
 | |
| 		voltage_mv *= 2;
 | |
| 
 | |
| 	dev_dbg(cw_bat->dev, "Read voltage: %d mV, raw=0x%04x\n",
 | |
| 		voltage_mv, reg_val);
 | |
| 
 | |
| 	return voltage_mv;
 | |
| }
 | |
| 
 | |
| static void cw_update_charge_status(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int ret;
 | |
| 
 | |
| 	ret = power_supply_am_i_supplied(cw_bat->rk_bat);
 | |
| 	if (ret < 0) {
 | |
| 		dev_warn(cw_bat->dev, "Failed to get supply state: %d\n", ret);
 | |
| 	} else {
 | |
| 		bool charger_attached;
 | |
| 
 | |
| 		charger_attached = !!ret;
 | |
| 		if (cw_bat->charger_attached != charger_attached) {
 | |
| 			cw_bat->battery_changed = true;
 | |
| 			if (charger_attached)
 | |
| 				cw_bat->charge_count++;
 | |
| 		}
 | |
| 		cw_bat->charger_attached = charger_attached;
 | |
| 	}
 | |
| }
 | |
| 
 | |
| static void cw_update_soc(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int soc;
 | |
| 
 | |
| 	soc = cw_get_soc(cw_bat);
 | |
| 	if (soc < 0)
 | |
| 		dev_err(cw_bat->dev, "Failed to get SoC from gauge: %d\n", soc);
 | |
| 	else if (cw_bat->soc != soc) {
 | |
| 		cw_bat->soc = soc;
 | |
| 		cw_bat->battery_changed = true;
 | |
| 	}
 | |
| }
 | |
| 
 | |
| static void cw_update_voltage(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int voltage_mv;
 | |
| 
 | |
| 	voltage_mv = cw_get_voltage(cw_bat);
 | |
| 	if (voltage_mv < 0)
 | |
| 		dev_err(cw_bat->dev, "Failed to get voltage from gauge: %d\n",
 | |
| 			voltage_mv);
 | |
| 	else
 | |
| 		cw_bat->voltage_mv = voltage_mv;
 | |
| }
 | |
| 
 | |
| static int cw_update_temp(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	unsigned int val = 0;
 | |
| 
 | |
| 	regmap_read(cw_bat->regmap, CW2017_REG_TEMP, &val);
 | |
| 	cw_bat->temp = val * 10 / 2 - 400;
 | |
| 
 | |
| 	return cw_bat->temp;
 | |
| }
 | |
| 
 | |
| static void cw_update_status(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	int status = POWER_SUPPLY_STATUS_DISCHARGING;
 | |
| 
 | |
| 	if (cw_bat->charger_attached) {
 | |
| 		if (cw_bat->soc >= 100)
 | |
| 			status = POWER_SUPPLY_STATUS_FULL;
 | |
| 		else
 | |
| 			status = POWER_SUPPLY_STATUS_CHARGING;
 | |
| 	}
 | |
| 
 | |
| 	if (cw_bat->status != status)
 | |
| 		cw_bat->battery_changed = true;
 | |
| 	cw_bat->status = status;
 | |
| }
 | |
| 
 | |
| static void cw_bat_work(struct work_struct *work)
 | |
| {
 | |
| 	struct delayed_work *delay_work;
 | |
| 	struct cw_battery *cw_bat;
 | |
| 
 | |
| 	delay_work = to_delayed_work(work);
 | |
| 	cw_bat = container_of(delay_work, struct cw_battery, battery_delay_work);
 | |
| 
 | |
| 	cw_update_soc(cw_bat);
 | |
| 	cw_update_voltage(cw_bat);
 | |
| 	cw_update_charge_status(cw_bat);
 | |
| 	cw_update_temp(cw_bat);
 | |
| 	cw_update_status(cw_bat);
 | |
| 
 | |
| 	dev_dbg(cw_bat->dev, "charger_attached = %d\n", cw_bat->charger_attached);
 | |
| 	dev_dbg(cw_bat->dev, "status = %d\n", cw_bat->status);
 | |
| 	dev_dbg(cw_bat->dev, "soc = %d%%\n", cw_bat->soc);
 | |
| 	dev_dbg(cw_bat->dev, "voltage = %dmV\n", cw_bat->voltage_mv);
 | |
| 
 | |
| 	if (cw_bat->battery_changed)
 | |
| 		power_supply_changed(cw_bat->rk_bat);
 | |
| 	cw_bat->battery_changed = false;
 | |
| 
 | |
| 	queue_delayed_work(cw_bat->battery_workqueue,
 | |
| 			   &cw_bat->battery_delay_work,
 | |
| 			   msecs_to_jiffies(cw_bat->poll_interval_ms));
 | |
| }
 | |
| 
 | |
| static int cw_battery_get_property(struct power_supply *psy,
 | |
| 				   enum power_supply_property psp,
 | |
| 				   union power_supply_propval *val)
 | |
| {
 | |
| 	struct cw_battery *cw_bat;
 | |
| 
 | |
| 	cw_bat = power_supply_get_drvdata(psy);
 | |
| 	switch (psp) {
 | |
| 	case POWER_SUPPLY_PROP_CAPACITY:
 | |
| 		val->intval = cw_bat->soc;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_STATUS:
 | |
| 		val->intval = cw_bat->status;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_PRESENT:
 | |
| 		val->intval = !!cw_bat->voltage_mv;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_VOLTAGE_NOW:
 | |
| 		val->intval = cw_bat->voltage_mv * 1000;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
 | |
| 		val->intval = 0;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_TECHNOLOGY:
 | |
| 		val->intval = POWER_SUPPLY_TECHNOLOGY_LION;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_CHARGE_COUNTER:
 | |
| 		val->intval = cw_bat->charge_count;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_TEMP:
 | |
| 		val->intval = cw_bat->temp;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_CHARGE_FULL:
 | |
| 	case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
 | |
| 		if (cw_bat->battery->charge_full_design_uah > 0)
 | |
| 			val->intval = cw_bat->battery->charge_full_design_uah;
 | |
| 		else
 | |
| 			val->intval = cw_bat->design_capacity * 1000;
 | |
| 		break;
 | |
| 
 | |
| 	case POWER_SUPPLY_PROP_CURRENT_NOW:
 | |
| 		val->intval = 0;
 | |
| 		break;
 | |
| 
 | |
| 	default:
 | |
| 		break;
 | |
| 	}
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static enum power_supply_property cw_battery_properties[] = {
 | |
| 	POWER_SUPPLY_PROP_CAPACITY,
 | |
| 	POWER_SUPPLY_PROP_STATUS,
 | |
| 	POWER_SUPPLY_PROP_PRESENT,
 | |
| 	POWER_SUPPLY_PROP_VOLTAGE_NOW,
 | |
| 	POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
 | |
| 	POWER_SUPPLY_PROP_TECHNOLOGY,
 | |
| 	POWER_SUPPLY_PROP_CHARGE_COUNTER,
 | |
| 	POWER_SUPPLY_PROP_TEMP,
 | |
| 	POWER_SUPPLY_PROP_CHARGE_FULL,
 | |
| 	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
 | |
| 	POWER_SUPPLY_PROP_CURRENT_NOW,
 | |
| };
 | |
| 
 | |
| static const struct power_supply_desc cw2017_bat_desc = {
 | |
| 	.name		= "cw2017-battery",
 | |
| 	.type		= POWER_SUPPLY_TYPE_BATTERY,
 | |
| 	.properties	= cw_battery_properties,
 | |
| 	.num_properties	= ARRAY_SIZE(cw_battery_properties),
 | |
| 	.get_property	= cw_battery_get_property,
 | |
| };
 | |
| 
 | |
| static int cw2017_parse_properties(struct cw_battery *cw_bat)
 | |
| {
 | |
| 	struct device *dev = cw_bat->dev;
 | |
| 	int length;
 | |
| 	int ret;
 | |
| 
 | |
| 	length = device_property_count_u8(dev, "cellwise,battery-profile");
 | |
| 	if (length < 0) {
 | |
| 		dev_warn(cw_bat->dev,
 | |
| 			 "No battery-profile found, using current flash contents\n");
 | |
| 	} else if (length != CW2017_SIZE_BATINFO) {
 | |
| 		dev_err(cw_bat->dev, "battery-profile must be %d bytes\n",
 | |
| 			CW2017_SIZE_BATINFO);
 | |
| 		return -EINVAL;
 | |
| 	}
 | |
| 
 | |
| 	cw_bat->bat_profile = devm_kzalloc(dev, length, GFP_KERNEL);
 | |
| 	if (!cw_bat->bat_profile)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	ret = device_property_read_u8_array(dev,
 | |
| 					    "cellwise,battery-profile",
 | |
| 					    cw_bat->bat_profile,
 | |
| 					    length);
 | |
| 	if (ret)
 | |
| 		return ret;
 | |
| 
 | |
| 	ret = device_property_read_u32(dev, "cellwise,design-capacity-amh",
 | |
| 				       &cw_bat->design_capacity);
 | |
| 	if (ret) {
 | |
| 		dev_info(cw_bat->dev, "Missing design capacity\n");
 | |
| 		cw_bat->design_capacity = DEF_DESIGN_CAPACITY;
 | |
| 	}
 | |
| 
 | |
| 	device_property_read_u32(dev, "cellwise,alert-level",
 | |
| 				 &cw_bat->alert_level);
 | |
| 
 | |
| 	cw_bat->dual_cell = device_property_read_bool(dev, "cellwise,dual-cell");
 | |
| 
 | |
| 	ret = device_property_read_u32(dev, "cellwise,monitor-interval-ms",
 | |
| 				       &cw_bat->poll_interval_ms);
 | |
| 	if (ret) {
 | |
| 		dev_dbg(cw_bat->dev, "Using default poll interval\n");
 | |
| 		cw_bat->poll_interval_ms = CW2017_DEFAULT_POLL_INTERVAL_MS;
 | |
| 	}
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static const struct regmap_range regmap_ranges_rd_yes[] = {
 | |
| 	regmap_reg_range(CW2017_REG_VERSION, CW2017_REG_VERSION),
 | |
| 	regmap_reg_range(CW2017_REG_VCELL_H, CW2017_REG_TEMP),
 | |
| 	regmap_reg_range(CW2017_REG_MODE_CONFIG, CW2017_REG_MODE_CONFIG),
 | |
| 	regmap_reg_range(CW2017_REG_INT_CONFIG,
 | |
| 			 CW2017_REG_BATINFO + CW2017_SIZE_BATINFO - 1),
 | |
| };
 | |
| 
 | |
| static const struct regmap_access_table regmap_rd_table = {
 | |
| 	.yes_ranges = regmap_ranges_rd_yes,
 | |
| 	.n_yes_ranges = ARRAY_SIZE(regmap_ranges_rd_yes),
 | |
| };
 | |
| 
 | |
| static const struct regmap_range regmap_ranges_wr_yes[] = {
 | |
| 	regmap_reg_range(CW2017_REG_MODE_CONFIG, CW2017_REG_MODE_CONFIG),
 | |
| 	regmap_reg_range(CW2017_REG_INT_CONFIG, CW2017_REG_TEMP_MIN),
 | |
| 	regmap_reg_range(CW2017_REG_BATINFO,
 | |
| 			 CW2017_REG_BATINFO + CW2017_SIZE_BATINFO - 1),
 | |
| };
 | |
| 
 | |
| static const struct regmap_access_table regmap_wr_table = {
 | |
| 	.yes_ranges = regmap_ranges_wr_yes,
 | |
| 	.n_yes_ranges = ARRAY_SIZE(regmap_ranges_wr_yes),
 | |
| };
 | |
| 
 | |
| static const struct regmap_range regmap_ranges_vol_yes[] = {
 | |
| 	regmap_reg_range(CW2017_REG_VCELL_H, CW2017_REG_TEMP),
 | |
| };
 | |
| 
 | |
| static const struct regmap_access_table regmap_vol_table = {
 | |
| 	.yes_ranges = regmap_ranges_vol_yes,
 | |
| 	.n_yes_ranges = ARRAY_SIZE(regmap_ranges_vol_yes),
 | |
| };
 | |
| 
 | |
| static const struct regmap_config cw2017_regmap_config = {
 | |
| 	.reg_bits = 8,
 | |
| 	.val_bits = 8,
 | |
| 	.rd_table = ®map_rd_table,
 | |
| 	.wr_table = ®map_wr_table,
 | |
| 	.volatile_table = ®map_vol_table,
 | |
| 	.max_register = CW2017_REG_BATINFO + CW2017_SIZE_BATINFO - 1,
 | |
| };
 | |
| 
 | |
| static int cw_bat_probe(struct i2c_client *client)
 | |
| {
 | |
| 	int ret;
 | |
| 	struct cw_battery *cw_bat;
 | |
| 	struct power_supply_config psy_cfg = { 0 };
 | |
| 
 | |
| 	cw_bat = devm_kzalloc(&client->dev, sizeof(*cw_bat), GFP_KERNEL);
 | |
| 	if (!cw_bat)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	i2c_set_clientdata(client, cw_bat);
 | |
| 	cw_bat->dev = &client->dev;
 | |
| 	cw_bat->soc = 1;
 | |
| 
 | |
| 	ret = cw2017_parse_properties(cw_bat);
 | |
| 	if (ret) {
 | |
| 		dev_err(cw_bat->dev, "Failed to parse cw2017 properties\n");
 | |
| 		return ret;
 | |
| 	}
 | |
| 
 | |
| 	cw_bat->regmap = devm_regmap_init_i2c(client, &cw2017_regmap_config);
 | |
| 	if (IS_ERR(cw_bat->regmap)) {
 | |
| 		dev_err(cw_bat->dev, "Failed to allocate regmap: %ld\n",
 | |
| 			PTR_ERR(cw_bat->regmap));
 | |
| 		return PTR_ERR(cw_bat->regmap);
 | |
| 	}
 | |
| 
 | |
| 	ret = cw_init(cw_bat);
 | |
| 	if (ret) {
 | |
| 		dev_err(cw_bat->dev, "Init failed: %d\n", ret);
 | |
| 		return ret;
 | |
| 	}
 | |
| 
 | |
| 	psy_cfg.drv_data = cw_bat;
 | |
| 	psy_cfg.fwnode = dev_fwnode(cw_bat->dev);
 | |
| 
 | |
| 	cw_bat->rk_bat = devm_power_supply_register(&client->dev,
 | |
| 						    &cw2017_bat_desc,
 | |
| 						    &psy_cfg);
 | |
| 	if (IS_ERR(cw_bat->rk_bat)) {
 | |
| 		/* try again if this happens */
 | |
| 		dev_err_probe(&client->dev, PTR_ERR(cw_bat->rk_bat),
 | |
| 			"Failed to register power supply\n");
 | |
| 		return PTR_ERR(cw_bat->rk_bat);
 | |
| 	}
 | |
| 
 | |
| 	ret = power_supply_get_battery_info(cw_bat->rk_bat, &cw_bat->battery);
 | |
| 	if (ret) {
 | |
| 		/* Allocate an empty battery */
 | |
| 		cw_bat->battery = devm_kzalloc(&client->dev,
 | |
| 					       sizeof(*cw_bat->battery),
 | |
| 					       GFP_KERNEL);
 | |
| 		if (!cw_bat->battery)
 | |
| 			return -ENOMEM;
 | |
| 		dev_warn(cw_bat->dev,
 | |
| 			 "No monitored battery, some properties will be missing\n");
 | |
| 	}
 | |
| 
 | |
| 	cw_bat->battery_workqueue = create_singlethread_workqueue("rk_battery");
 | |
| 	if (!cw_bat->battery_workqueue)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	devm_delayed_work_autocancel(&client->dev,
 | |
| 				     &cw_bat->battery_delay_work, cw_bat_work);
 | |
| 	queue_delayed_work(cw_bat->battery_workqueue,
 | |
| 			   &cw_bat->battery_delay_work, msecs_to_jiffies(10));
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static int __maybe_unused cw_bat_suspend(struct device *dev)
 | |
| {
 | |
| 	struct i2c_client *client = to_i2c_client(dev);
 | |
| 	struct cw_battery *cw_bat = i2c_get_clientdata(client);
 | |
| 
 | |
| 	cancel_delayed_work_sync(&cw_bat->battery_delay_work);
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static int __maybe_unused cw_bat_resume(struct device *dev)
 | |
| {
 | |
| 	struct i2c_client *client = to_i2c_client(dev);
 | |
| 	struct cw_battery *cw_bat = i2c_get_clientdata(client);
 | |
| 
 | |
| 	queue_delayed_work(cw_bat->battery_workqueue,
 | |
| 			   &cw_bat->battery_delay_work, 0);
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static SIMPLE_DEV_PM_OPS(cw_bat_pm_ops, cw_bat_suspend, cw_bat_resume);
 | |
| 
 | |
| static const struct i2c_device_id cw_bat_id_table[] = {
 | |
| 	{ "cw2017", 0 },
 | |
| 	{ }
 | |
| };
 | |
| 
 | |
| static const struct of_device_id cw2017_of_match[] = {
 | |
| 	{ .compatible = "cellwise,cw2017" },
 | |
| 	{ }
 | |
| };
 | |
| MODULE_DEVICE_TABLE(of, cw2017_of_match);
 | |
| 
 | |
| static struct i2c_driver cw_bat_driver = {
 | |
| 	.driver = {
 | |
| 		.name = "cw2017",
 | |
| 		.of_match_table = cw2017_of_match,
 | |
| 		.pm = &cw_bat_pm_ops,
 | |
| 	},
 | |
| 	.probe_new = cw_bat_probe,
 | |
| 	.id_table = cw_bat_id_table,
 | |
| };
 | |
| 
 | |
| module_i2c_driver(cw_bat_driver);
 | |
| 
 | |
| MODULE_AUTHOR("Shunqing Chen<csq@rock-chips.com>");
 | |
| MODULE_DESCRIPTION("cw2017 battery driver");
 | |
| MODULE_LICENSE("GPL");
 |