What:		/sys/bus/iio/devices/triggerX/trigger_polarity
 | 
						|
KernelVersion:	4.11
 | 
						|
Contact:	fabrice.gasnier@st.com
 | 
						|
Description:
 | 
						|
		The STM32 ADC can be configured to use external trigger sources
 | 
						|
		(e.g. timers, pwm or exti gpio). Then, it can be tuned to start
 | 
						|
		conversions on external trigger by either:
 | 
						|
 | 
						|
		- "rising-edge"
 | 
						|
		- "falling-edge"
 | 
						|
		- "both-edges".
 | 
						|
 | 
						|
		Reading returns current trigger polarity.
 | 
						|
 | 
						|
		Writing value before enabling conversions sets trigger polarity.
 | 
						|
 | 
						|
What:		/sys/bus/iio/devices/triggerX/trigger_polarity_available
 | 
						|
KernelVersion:	4.11
 | 
						|
Contact:	fabrice.gasnier@st.com
 | 
						|
Description:
 | 
						|
		List all available trigger_polarity settings.
 |