// SPDX-License-Identifier: GPL-2.0
 | 
						|
/*
 | 
						|
 * Siemens SIMATIC IPC platform driver
 | 
						|
 *
 | 
						|
 * Copyright (c) Siemens AG, 2018-2021
 | 
						|
 *
 | 
						|
 * Authors:
 | 
						|
 *  Henning Schild <henning.schild@siemens.com>
 | 
						|
 *  Jan Kiszka <jan.kiszka@siemens.com>
 | 
						|
 *  Gerd Haeussler <gerd.haeussler.ext@siemens.com>
 | 
						|
 */
 | 
						|
 | 
						|
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
 | 
						|
 | 
						|
#include <linux/dmi.h>
 | 
						|
#include <linux/kernel.h>
 | 
						|
#include <linux/module.h>
 | 
						|
#include <linux/pci.h>
 | 
						|
#include <linux/platform_data/x86/simatic-ipc.h>
 | 
						|
#include <linux/platform_device.h>
 | 
						|
 | 
						|
static struct platform_device *ipc_led_platform_device;
 | 
						|
static struct platform_device *ipc_wdt_platform_device;
 | 
						|
 | 
						|
static const struct dmi_system_id simatic_ipc_whitelist[] = {
 | 
						|
	{
 | 
						|
		.matches = {
 | 
						|
			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
 | 
						|
		},
 | 
						|
	},
 | 
						|
	{}
 | 
						|
};
 | 
						|
 | 
						|
static struct simatic_ipc_platform platform_data;
 | 
						|
 | 
						|
static struct {
 | 
						|
	u32 station_id;
 | 
						|
	u8 led_mode;
 | 
						|
	u8 wdt_mode;
 | 
						|
} device_modes[] = {
 | 
						|
	{SIMATIC_IPC_IPC127E, SIMATIC_IPC_DEVICE_127E, SIMATIC_IPC_DEVICE_NONE},
 | 
						|
	{SIMATIC_IPC_IPC227D, SIMATIC_IPC_DEVICE_227D, SIMATIC_IPC_DEVICE_NONE},
 | 
						|
	{SIMATIC_IPC_IPC227E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_227E},
 | 
						|
	{SIMATIC_IPC_IPC227G, SIMATIC_IPC_DEVICE_227G, SIMATIC_IPC_DEVICE_227G},
 | 
						|
	{SIMATIC_IPC_IPC277E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_227E},
 | 
						|
	{SIMATIC_IPC_IPC427D, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_NONE},
 | 
						|
	{SIMATIC_IPC_IPC427E, SIMATIC_IPC_DEVICE_427E, SIMATIC_IPC_DEVICE_427E},
 | 
						|
	{SIMATIC_IPC_IPC477E, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_427E},
 | 
						|
	{SIMATIC_IPC_IPCBX_39A, SIMATIC_IPC_DEVICE_227G, SIMATIC_IPC_DEVICE_227G},
 | 
						|
	{SIMATIC_IPC_IPCPX_39A, SIMATIC_IPC_DEVICE_NONE, SIMATIC_IPC_DEVICE_227G},
 | 
						|
};
 | 
						|
 | 
						|
static int register_platform_devices(u32 station_id)
 | 
						|
{
 | 
						|
	u8 ledmode = SIMATIC_IPC_DEVICE_NONE;
 | 
						|
	u8 wdtmode = SIMATIC_IPC_DEVICE_NONE;
 | 
						|
	char *pdevname = KBUILD_MODNAME "_leds";
 | 
						|
	int i;
 | 
						|
 | 
						|
	platform_data.devmode = SIMATIC_IPC_DEVICE_NONE;
 | 
						|
 | 
						|
	for (i = 0; i < ARRAY_SIZE(device_modes); i++) {
 | 
						|
		if (device_modes[i].station_id == station_id) {
 | 
						|
			ledmode = device_modes[i].led_mode;
 | 
						|
			wdtmode = device_modes[i].wdt_mode;
 | 
						|
			break;
 | 
						|
		}
 | 
						|
	}
 | 
						|
 | 
						|
	if (ledmode != SIMATIC_IPC_DEVICE_NONE) {
 | 
						|
		if (ledmode == SIMATIC_IPC_DEVICE_127E ||
 | 
						|
		    ledmode == SIMATIC_IPC_DEVICE_227G)
 | 
						|
			pdevname = KBUILD_MODNAME "_leds_gpio";
 | 
						|
		platform_data.devmode = ledmode;
 | 
						|
		ipc_led_platform_device =
 | 
						|
			platform_device_register_data(NULL,
 | 
						|
				pdevname, PLATFORM_DEVID_NONE,
 | 
						|
				&platform_data,
 | 
						|
				sizeof(struct simatic_ipc_platform));
 | 
						|
		if (IS_ERR(ipc_led_platform_device))
 | 
						|
			return PTR_ERR(ipc_led_platform_device);
 | 
						|
 | 
						|
		pr_debug("device=%s created\n",
 | 
						|
			 ipc_led_platform_device->name);
 | 
						|
	}
 | 
						|
 | 
						|
	if (wdtmode == SIMATIC_IPC_DEVICE_227G) {
 | 
						|
		request_module("w83627hf_wdt");
 | 
						|
		return 0;
 | 
						|
	}
 | 
						|
 | 
						|
	if (wdtmode != SIMATIC_IPC_DEVICE_NONE) {
 | 
						|
		platform_data.devmode = wdtmode;
 | 
						|
		ipc_wdt_platform_device =
 | 
						|
			platform_device_register_data(NULL,
 | 
						|
				KBUILD_MODNAME "_wdt", PLATFORM_DEVID_NONE,
 | 
						|
				&platform_data,
 | 
						|
				sizeof(struct simatic_ipc_platform));
 | 
						|
		if (IS_ERR(ipc_wdt_platform_device))
 | 
						|
			return PTR_ERR(ipc_wdt_platform_device);
 | 
						|
 | 
						|
		pr_debug("device=%s created\n",
 | 
						|
			 ipc_wdt_platform_device->name);
 | 
						|
	}
 | 
						|
 | 
						|
	if (ledmode == SIMATIC_IPC_DEVICE_NONE &&
 | 
						|
	    wdtmode == SIMATIC_IPC_DEVICE_NONE) {
 | 
						|
		pr_warn("unsupported IPC detected, station id=%08x\n",
 | 
						|
			station_id);
 | 
						|
		return -EINVAL;
 | 
						|
	}
 | 
						|
 | 
						|
	return 0;
 | 
						|
}
 | 
						|
 | 
						|
static int __init simatic_ipc_init_module(void)
 | 
						|
{
 | 
						|
	const struct dmi_system_id *match;
 | 
						|
	u32 station_id;
 | 
						|
	int err;
 | 
						|
 | 
						|
	match = dmi_first_match(simatic_ipc_whitelist);
 | 
						|
	if (!match)
 | 
						|
		return 0;
 | 
						|
 | 
						|
	err = dmi_walk(simatic_ipc_find_dmi_entry_helper, &station_id);
 | 
						|
 | 
						|
	if (err || station_id == SIMATIC_IPC_INVALID_STATION_ID) {
 | 
						|
		pr_warn("DMI entry %d not found\n", SIMATIC_IPC_DMI_ENTRY_OEM);
 | 
						|
		return 0;
 | 
						|
	}
 | 
						|
 | 
						|
	return register_platform_devices(station_id);
 | 
						|
}
 | 
						|
 | 
						|
static void __exit simatic_ipc_exit_module(void)
 | 
						|
{
 | 
						|
	platform_device_unregister(ipc_led_platform_device);
 | 
						|
	ipc_led_platform_device = NULL;
 | 
						|
 | 
						|
	platform_device_unregister(ipc_wdt_platform_device);
 | 
						|
	ipc_wdt_platform_device = NULL;
 | 
						|
}
 | 
						|
 | 
						|
module_init(simatic_ipc_init_module);
 | 
						|
module_exit(simatic_ipc_exit_module);
 | 
						|
 | 
						|
MODULE_LICENSE("GPL v2");
 | 
						|
MODULE_AUTHOR("Gerd Haeussler <gerd.haeussler.ext@siemens.com>");
 | 
						|