| What:		/sys/bus/counter/devices/counterX/countY/count
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count data of Count Y represented as a string.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/capture
 | |
| KernelVersion:	6.1
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Historical capture of the Count Y count data.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/ceiling
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count value ceiling for Count Y. This is the upper limit for the
 | |
| 		respective counter.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/floor
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count value floor for Count Y. This is the lower limit for the
 | |
| 		respective counter.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/count_mode
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count mode for channel Y. The ceiling and floor values for
 | |
| 		Count Y are used by the count mode where required. The following
 | |
| 		count modes are available:
 | |
| 
 | |
| 		normal:
 | |
| 			Counting is continuous in either direction.
 | |
| 
 | |
| 		range limit:
 | |
| 			An upper or lower limit is set, mimicking limit switches
 | |
| 			in the mechanical counterpart. The upper limit is set to
 | |
| 			the Count Y ceiling value, while the lower limit is set
 | |
| 			to the Count Y floor value. The counter freezes at
 | |
| 			count = ceiling when counting up, and at count = floor
 | |
| 			when counting down. At either of these limits, the
 | |
| 			counting is resumed only when the count direction is
 | |
| 			reversed.
 | |
| 
 | |
| 		non-recycle:
 | |
| 			The counter is disabled whenever a counter overflow or
 | |
| 			underflow takes place. The counter is re-enabled when a
 | |
| 			new count value is loaded to the counter via a preset
 | |
| 			operation or direct write.
 | |
| 
 | |
| 		modulo-n:
 | |
| 			A count value boundary is set between the Count Y floor
 | |
| 			value and the Count Y ceiling value. The counter is
 | |
| 			reset to the Count Y floor value at count = ceiling when
 | |
| 			counting up, while the counter is set to the Count Y
 | |
| 			ceiling value at count = floor when counting down; the
 | |
| 			counter does not freeze at the boundary points, but
 | |
| 			counts continuously throughout.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/count_mode_available
 | |
| What:		/sys/bus/counter/devices/counterX/countY/error_noise_available
 | |
| What:		/sys/bus/counter/devices/counterX/countY/function_available
 | |
| What:		/sys/bus/counter/devices/counterX/countY/prescaler_available
 | |
| What:		/sys/bus/counter/devices/counterX/countY/signalZ_action_available
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Discrete set of available values for the respective Count Y
 | |
| 		configuration are listed in this file. Values are delimited by
 | |
| 		newline characters.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/direction
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the count direction of Count
 | |
| 		Y. Two count directions are available: forward and backward.
 | |
| 
 | |
| 		Some counter devices are able to determine the direction of
 | |
| 		their counting. For example, quadrature encoding counters can
 | |
| 		determine the direction of movement by evaluating the leading
 | |
| 		phase of the respective A and B quadrature encoding signals.
 | |
| 		This attribute exposes such count directions.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/enable
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Whether channel Y counter is enabled. Valid attribute values are
 | |
| 		boolean.
 | |
| 
 | |
| 		This attribute is intended to serve as a pause/unpause mechanism
 | |
| 		for Count Y. Suppose a counter device is used to count the total
 | |
| 		movement of a conveyor belt: this attribute allows an operator
 | |
| 		to temporarily pause the counter, service the conveyor belt,
 | |
| 		and then finally unpause the counter to continue where it had
 | |
| 		left off.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/error_noise
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates whether excessive noise is
 | |
| 		present at the channel Y counter inputs.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/function
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count function mode of Count Y; count function evaluation is
 | |
| 		triggered by conditions specified by the Count Y signalZ_action
 | |
| 		attributes. The following count functions are available:
 | |
| 
 | |
| 		increase:
 | |
| 			Accumulated count is incremented.
 | |
| 
 | |
| 		decrease:
 | |
| 			Accumulated count is decremented.
 | |
| 
 | |
| 		pulse-direction:
 | |
| 			Rising edges on signal A updates the respective count.
 | |
| 			The input level of signal B determines direction.
 | |
| 
 | |
| 		quadrature x1 a:
 | |
| 			If direction is forward, rising edges on quadrature pair
 | |
| 			signal A updates the respective count; if the direction
 | |
| 			is backward, falling edges on quadrature pair signal A
 | |
| 			updates the respective count. Quadrature encoding
 | |
| 			determines the direction.
 | |
| 
 | |
| 		quadrature x1 b:
 | |
| 			If direction is forward, rising edges on quadrature pair
 | |
| 			signal B updates the respective count; if the direction
 | |
| 			is backward, falling edges on quadrature pair signal B
 | |
| 			updates the respective count. Quadrature encoding
 | |
| 			determines the direction.
 | |
| 
 | |
| 		quadrature x2 a:
 | |
| 			Any state transition on quadrature pair signal A updates
 | |
| 			the respective count. Quadrature encoding determines the
 | |
| 			direction.
 | |
| 
 | |
| 		quadrature x2 b:
 | |
| 			Any state transition on quadrature pair signal B updates
 | |
| 			the respective count. Quadrature encoding determines the
 | |
| 			direction.
 | |
| 
 | |
| 		quadrature x4:
 | |
| 			Any state transition on either quadrature pair signals
 | |
| 			updates	the respective count. Quadrature encoding
 | |
| 			determines the direction.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/name
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the device-specific name of
 | |
| 		Count Y. If possible, this should match the name of the
 | |
| 		respective channel as it appears in the device datasheet.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/prescaler
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Configure the prescaler value associated with Count Y.
 | |
| 		On the FlexTimer, the counter clock source passes through a
 | |
| 		prescaler (i.e. a counter). This acts like a clock
 | |
| 		divider.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/preset
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		If the counter device supports preset registers -- registers
 | |
| 		used to load counter channels to a set count upon device-defined
 | |
| 		preset operation trigger events -- the preset count for channel
 | |
| 		Y is provided by this attribute.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/preset_enable
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Whether channel Y counter preset operation is enabled. Valid
 | |
| 		attribute values are boolean.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/signalZ_action
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Action mode of Count Y for Signal Z. This attribute indicates
 | |
| 		the condition of Signal Z that triggers the count function
 | |
| 		evaluation for Count Y. The following action modes are
 | |
| 		available:
 | |
| 
 | |
| 		none:
 | |
| 			Signal does not trigger the count function. In
 | |
| 			Pulse-Direction count function mode, this Signal is
 | |
| 			evaluated as Direction.
 | |
| 
 | |
| 		rising edge:
 | |
| 			Low state transitions to high state.
 | |
| 
 | |
| 		falling edge:
 | |
| 			High state transitions to low state.
 | |
| 
 | |
| 		both edges:
 | |
| 			Any state transition.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/num_overflows
 | |
| KernelVersion:	6.1
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		This attribute indicates the number of overflows of count Y.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/capture_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/ceiling_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/floor_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/count_mode_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/direction_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/enable_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/error_noise_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/prescaler_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/preset_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/preset_enable_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/signalZ_action_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/countY/num_overflows_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/polarity_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/frequency_component_id
 | |
| KernelVersion:	5.16
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the component ID of the
 | |
| 		respective extension or Synapse.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/countY/spike_filter_ns
 | |
| KernelVersion:	5.14
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		If the counter device supports programmable spike filter this
 | |
| 		attribute indicates the value in nanoseconds where noise pulses
 | |
| 		shorter or equal to configured value are ignored. Value 0 means
 | |
| 		filter is disabled.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/events_queue_size
 | |
| KernelVersion:	5.16
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Size of the Counter events queue in number of struct
 | |
| 		counter_event data structures. The number of elements will be
 | |
| 		rounded-up to a power of 2.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/name
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the device-specific name of
 | |
| 		the Counter. This should match the name of the device as it
 | |
| 		appears in its respective datasheet.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/num_counts
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the total number of Counts
 | |
| 		belonging to the Counter.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/num_signals
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the total number of Signals
 | |
| 		belonging to the Counter.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/cable_fault
 | |
| KernelVersion:	5.7
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates whether a differential
 | |
| 		encoder cable fault (not connected or loose wires) is detected
 | |
| 		for the respective channel of Signal Y. Valid attribute values
 | |
| 		are boolean. Detection must first be enabled via the
 | |
| 		corresponding cable_fault_enable attribute.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/cable_fault_enable
 | |
| KernelVersion:	5.7
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Whether detection of differential encoder cable faults for the
 | |
| 		respective channel of Signal Y is enabled. Valid attribute
 | |
| 		values are boolean.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
 | |
| KernelVersion:	5.7
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Filter clock factor for input Signal Y. This prescaler value
 | |
| 		affects the inputs of both quadrature pair signals.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/index_polarity
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Active level of index input Signal Y; irrelevant in
 | |
| 		non-synchronous load mode.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Discrete set of available values for the respective Signal Y
 | |
| 		configuration are listed in this file.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/polarity
 | |
| KernelVersion:	6.1
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Active level of Signal Y. The following polarity values are
 | |
| 		available:
 | |
| 
 | |
| 		positive:
 | |
| 			Signal high state considered active level (rising edge).
 | |
| 
 | |
| 		negative:
 | |
| 			Signal low state considered active level (falling edge).
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/name
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the device-specific name of
 | |
| 		Signal Y. If possible, this should match the name of the
 | |
| 		respective signal as it appears in the device datasheet.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/signal
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Signal level state of Signal Y. The following signal level
 | |
| 		states are available:
 | |
| 
 | |
| 		low:
 | |
| 			Low level state.
 | |
| 
 | |
| 		high:
 | |
| 			High level state.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode
 | |
| KernelVersion:	5.2
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Configure the counter associated with Signal Y for
 | |
| 		non-synchronous or synchronous load mode. Synchronous load mode
 | |
| 		cannot be selected in non-quadrature (Pulse-Direction) clock
 | |
| 		mode.
 | |
| 
 | |
| 		non-synchronous:
 | |
| 			A logic low level is the active level at this index
 | |
| 			input. The index function (as enabled via preset_enable)
 | |
| 			is performed directly on the active level of the index
 | |
| 			input.
 | |
| 
 | |
| 		synchronous:
 | |
| 			Intended for interfacing with encoder Index output in
 | |
| 			quadrature clock mode. The active level is configured
 | |
| 			via index_polarity. The index function (as enabled via
 | |
| 			preset_enable) is performed synchronously with the
 | |
| 			quadrature clock on the active level of the index input.
 | |
| 
 | |
| What:		/sys/bus/counter/devices/counterX/signalY/frequency
 | |
| KernelVersion:	6.1
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates the signal Y frequency, in Hz.
 |