What:		/sys/bus/iio/devices/iio:deviceX/fault_ovuv
 | 
						|
KernelVersion:	5.1
 | 
						|
Contact:	linux-iio@vger.kernel.org
 | 
						|
Description:
 | 
						|
		Overvoltage or Undervoltage Input Fault. The internal circuitry
 | 
						|
		is protected from excessive voltages applied to the thermocouple
 | 
						|
		cables. The device can also detect if such a condition occurs.
 | 
						|
 | 
						|
		Reading returns '1' if input voltage is negative or greater
 | 
						|
		than VDD, otherwise '0'.
 | 
						|
 | 
						|
What:		/sys/bus/iio/devices/iio:deviceX/fault_oc
 | 
						|
KernelVersion:	5.1
 | 
						|
Contact:	linux-iio@vger.kernel.org
 | 
						|
Description:
 | 
						|
		Open-circuit fault. The detection of open-circuit faults,
 | 
						|
		such as those caused by broken thermocouple wires.
 | 
						|
		Reading returns '1' if fault, '0' otherwise.
 |